PC6 Encoder to Counter Interface Board

The PC6 is no longer available for purchase.

PC6 Product Description

The PC6 decodes the quadrature outputs of an incremental shaft encoder to drive standard up/down counters. The PC6-U, up count / down count version, can be connected to the inputs of common counters such as a 74193 or 40193. The PC6-C, clock, and direction version, can connect directly to the counters such as 4516 or 74169.

Please note: The encoder interface IC used in this product can be purchased separately (see the LS7183N-S & LS7184N-S pages).

Specifications

ENVIRONMENTAL

PARAMETER MIN. MAX. UNITS
Operating Temperature -40 70 °C
Electrostatic Discharge, Human Body Model -2 2 kV

MECHANICAL

ELECTRICAL

PARAMETER MIN. MAX. UNITS NOTES
Supply Voltage 4.5 5.5 Volts -
Supply Current - 100 µA A,B = 100KHz
A,B Logic Low - 0.6 Volts -
A,B Logic High 3.1 - Volts -
A,B Frequency - 180 kHz -
Sink Output Current 1.75 - mA Vout = 0.4V
Source Output Current 1.0 - mA Vout = 4.5V
Pulse Width of Clock Output 4.0 8.0 µS 6µS typical

* The clock output pulse width is 6µS.

PIN DESCRIPTIONS



PC6-X-X-X INPUT PIN-OUT

PIN NAME DESCRIPTION
1 GND Ground
2 I Index
3 A A channel
4 VCC +5 VCC
5 B B channel



PC6-U-X-X OUTPUT PIN-OUT. UP COUNT / DOWN COUNT (LFLS7183)

PIN NAME DESCRIPTION
1 GND Ground
2 I Index
3 /DNCK Down clock
4 VCC +5 VCC
5 /UPCK Up clock



PC6-C-X-X OUTPUT PIN-OUT. CLOCK, UP/DN (LFLS7184)

PIN NAME DESCRIPTION
1 GND Ground
2 I Index
3 UP/DN Up/Down
4 VCC +5 VCC
5 /CLK Clock output



Index (Pin 2)

The index signal is routed unchanged, directly from the encoder.

PC6-U-x, pin 3 (LFLS7183).

Normally high, low-true. Down counts are enabled only when B leads A (clockwise rotation). One pulse is generated per encoder cycle using the PC6-U-1 and four pulses are generated using the PC6-U-4. For example, a 500 CPR encoder will produce five hundred clocks/rev. using the PC6-U-1 and 2000 clocks/rev. using the PC6-U-4. The external counter should count on the rising (high-going) edge of this output.

PC6-U-x, pin 5 (LFLS7183).

Normally high, low-true. Up counts are enabled only when A leads B (counterclockwise rotation). One pulse is generated per encoder cycle using the PC6-U-1 and four pulses are generated using the PC6-U-4. For example, a 500 CPR encoder will produce 500 clocks/rev. using the PC6-U-1 and 2000 clocks/rev. using the PC6-U-4. The external counter should count on the rising (high-going) edge of this output.

PC6-C-x, pin 3 (LFLS7184)

This output steers the external counter up or down. High = Up (A leads B), Low = Down (B leads A).

PC6-C-x, pin 5 (LFLS7184)

Normally high, low-true. One pulse is generated per encoder cycle using the PC6-C-1 and four pulses are generated using the PC6-C-4. For example, a 500 CPR encoder will produce 500 clocks/rev. using the PC6-C-1 and 2000 clocks/rev. using the PC6-C-4. The external counter should count on the rising (high-going) edge of this output.

Connector

The output connector on the PC6 is TE#640456-5. 

TIMING DIAGRAMS

PC6-U-X-X, UP COUNT / DOWN COUNT (LFLS7183)


PC6-C-X-X, CLOCK, UP/DN (LFLS7184)

Notes

  • For ordering information please see the Compatible Cables / Connectors section above.
  • US Digital® warrants its products against defects in materials and workmanship for two years. See complete warranty for details.

Configuration Options

PC6 -Output
U (Up and Down Clock)
C (Clock and Direction)
-Mode
1 (X1 Multiplication)
4 (X4 Multiplication)
-Connector
H5 (H5 Header)

PLEASE NOTE: This chart is for informational use only. Certain product configuration combinations are not available. Visit the PC6 product page for pricing and additional information.