The AD2B adapter allows the RS-485-like signal of SEI devices to interface to a standard RS-232 port (9-pin DB), such as those in IBM compatible PCs. The SEI (Serial Encoder Interface) bus is a simple, quick and convenient network of SEI devices interfacing to a RS-232 serial port. The SEI bus supports from 1 to 15 devices on a single 6-wire telephone-type cable, up to 1000 feet long. For more information on the SEI bus please see the SEI page.The AD2B has 2 differential signals to...
Specifications apply over entire operating temperature range.
| Parameter | Min. | Typ. | Max. | Units | Notes |
|---|---|---|---|---|---|
| Supply Voltage | 8.0 | - | 16 | Volts | - |
| Supply Current (without encoders) | - | - | 15 | mA | - |
| Differential SEI Output voltage |DataL - DataH|, |Busy+ - Busy-| |
2.0 | 2.75 | 5.0 | Volts | Load = 100Ω |
| Differential SEI Input Voltage |DataL - DataH|, |Busy+ - Busy-| |
0.2 | - | 5.0 | Volts | - |
| Common Mode SEI Output Voltage (DataH + DataL)/2, (Busy- + Busy+)/2 |
2.0 | 2.5 | 3.0 | Volts | Load = 100Ω |
| Common Mode SEI Input Voltage (DataH + DataL)/2, (Busy- + Busy+)/2 |
-4.5 | - | 3.0 | Volts | - |
| Input current DataH, DataL, Busy-, Busy+ |
-15 | - | 15 | mA | In = 0 to 5V |
| RS-232 Output | ±5.0 | ±8.0 | - | Volts | - |
| RS-232 Input | ±3.5 | - | ±15 | Volts | - |
| RS-232 Input Resistance | 3 | 5 | 7 | kΩ | - |
The AD2B adapter allows the RS-485-like signal of SEI devices to interface to a standard RS-232 port (9-pin DB), such as those in IBM compatible PCs. The SEI (Serial Encoder Interface) bus is a simple, quick and convenient network of SEI devices interfacing to a RS-232 serial port. The SEI bus supports from 1 to 15 devices on a single 6-wire telephone-type cable, up to 1000 feet long. For more information on the SEI bus please see the SEI page.
The AD2B has 2 differential signals to interface to SEI devices: the bidirectional data pair for communication, and the busy input pair for data flow control. The PS-12 power supply connects to the AD2B and furnishes power for all SEI devices on the bus.