Unless otherwise specified, all accuracy measurements assume operation within temperature range 0C to 70C.
| Parameter | Min. | Typ. | Max. | Units | Notes |
| Voltage Out to Encoder |
4.8 |
5.0 |
5.2 |
Volts |
Under 100mA load |
| Input Supply Voltage |
12 |
-
|
16 |
Volts |
|
| Supply Current |
- - |
110 255 |
- - |
mA mA |
12V input, no encoder load 12V input, 250mA encoder load |
| Full Scale Output Error - Analog Output |
-0.5 -1.5 |
0.25 ±0.25 |
0.5 1.5 |
% full scale % full scale |
0 - 4.095V output range 0 - 10V output range |
| Integral Non-linearity Error - Analog Output |
-3.0 -8.0 |
±1.0 ±3.0 |
3.0 8.0 |
mV mV |
0 - 4.095V output range 0 - 10V output range |
| Offset Error - Analog Output |
-6.0 -6.0 |
±1.0 ±1.0 |
6.0 6.0 |
mV mV |
0 - 4.095V output range 0 - 10V output range |
Quadrature Encoder Inputs* Logic Low Logic High |
0 2.0 |
0.4 5.0 |
0.8 5.75 |
Volts Volts |
|
Direction Bit Output Logic Low Logic High |
- 2.4 |
- - |
0.4 - |
Volts Volts |
8mA (sinking current) -4mA (sourching current) |
| Analog Output Load Impedance |
2000 |
- |
- |
Ohms |
|
* Diode clamped to ground and +5V, 5kΩ pullup to +5V.
| Parameter | Min. | Typ. | Max. | Units |
| Operating Temperature |
0 |
- |
70 |
C |
| Encoder Current* |
0 |
- |
250 |
mA |
| Quadrature Input Frequency |
0 |
- |
400 |
kHz |
* +5VDC power for external encoder.
The EDAC2 is programmed by eight DIP switches in either an up or down position.
| Switch | Name | Up ↑ | Down ↓ | Explanation |
| 0 |
Not Used |
- |
- |
- |
| 1 |
Reset |
Mid-range |
Zero |
Reset voltage level |
| 2 |
Range Limit |
Range Limit |
Rollover |
Sets counting mode |
| 3 |
Count Multiplier |
1X |
4X |
Enables quadrature counting |
| 4 |
Analog Voltage |
4.095V |
10V |
Sets full scale output voltage |
| 5 |
Reverse |
A / B |
B / A |
Swaps increasing count direction |
| 6 |
Index |
Reset |
No Reset |
Ignores the index or resets on index |
| 7 |
Output Mode |
Unipolar |
Bipolar |
0 to +VDC or ±VDC output |