Dis (Display Tachometer Units)
Four tachometer display units can be selected:
- RP60 (RPM) Revolutions per Minute
- RP1 (RPS) Revolutions per Second
- CP60 (CPM) Counts per Minute
- CP1 (CPS) Counts per Second

CPR
Enter the resolution (CPR) of the external encoder, full quadrature cycles per revolution.
This must be a positive integer value.

Scale Factor
Set this number to 1 if the encoder to shaft ratio is 1:1, the encoder resolution has been entered, and the above units are desired. Other values can be entered for other situations such as compensation for gearing between the shaft and the encoder. The velocity is multiplied by this factor to display numbers in more meaningful user units.
A negative scale factor (minus sign in the left-most digit) will reverse the displayed velocity. If desired, a decimal point may be placed by using the Decimal and Right Arrow buttons. Use any non-zero number.
NOTE: The Scale Factor resolution has no effect on the displayed resolution.

Hi Set
The High LED will be lit whenever the display velocity is greater than this value. If the Relay Mode is set to Hi, the Relay will be energized. If the Relay Mode is set to Bt (Between), the Relay will be energized and the Match LED will light when the display velocity is >=Lo Set and <=Hi Set. To disable this condition, set Hi Set greater than the highest attainable velocity.
NOTE: Placement of the decimal point in HI Set or Lo Set controls the number of decimal digits displayed during operation. The HI Set or Lo Set resolution can't be set any finer than the Scale Factor resolution. Encoder CPR and requested display resolution will affect the display update time.

Lo Set
The Low LED will be lit whenever the display velocity is less than this value. If the Relay Mode is set to Lo, the Relay will be energized. If the Relay Mode is set to Bt (Between), the Relay will be energized and the Match LED will light when the display velocity is >=Lo Set and <=Hi Set. To disable this condition, set Lo Set less than the lowest attainable (or negative) velocity.
NOTE: Placement of the decimal point in HI Set or Lo Set controls the number of decimal digits displayed during operation. The HI Set or Lo Set resolution can't be set any finer than the Scale Factor resolution. Encoder CPR and requested display resolution will affect the display update time.

Relay
The relay can be energized when the following conditions occur:
- No Never
- Hi When the display number is >Hi Set
- Lo When the display number is
- Bt (Between) - When the display number is >=Lo Set and <=Hi Set

Mode
The following Mode choices are available:
- Quad 1
- Quad 2
- Quad 4
- Step Dir (Step and Direction)
Quad 1 will cause the ED3 to count once per quadrature cycle (X1 mode), Quad 2 will count twice per quadrature cycle (X2 Mode) and Quad 4 will count four times per quadrature cycle (X4 mode). The Step Dir mode will accept non-quadrature pulses on the A input; the count direction is controlled by the B input (Input B may switch state only when input A = 1). The Step Dir mode is only valid when the CP1 and CP60 display output is selected.
Examples: If the ED3 receives 360 quadrature cycles, Quad 1 will generate 360 increments, Quad 4 will generate 1440 increments. In the Counts-Per-Time modes (CP1, CP60), the displayed rotational velocity in Quad 4 will be 4 times that of Quad 1; in the Revolutions-Per-Time modes (RP1, RP60), the displayed velocity will be calculated using Quad 4 mode only (other counting modes are ignored).

Abs (Absolute Value Mode)
The "Yes" selection will display all velocities as positive numbers regardless of the shaft direction. The "No" selection will display positive velocities in one direction and negative in the other.

Pre (Preset Button Enable)
When the preset button is pressed the velocities at that instant will be stored as target velocities and the display set to zero. That target will thereafter be subtracted from the current velocities to display the relative difference above and below that target. Pressing and holding the preset button for three seconds will return to the normal mode of displaying the actual velocities.

Lite (Backlight Default Setting)
When the ED3 first powers on, the backlight will automatically be turned on if this parameter is set to On, or Off if this parameter is set to Off. This parameter does not affect the front panel backlight button. It is always enabled and will toggle the backlight on or off.